Specialty Protection for Medium-Voltage Systems

R.C. Snubbers

Passive resistor-capacitor networks designed to absorb switching transients and protect medium-voltage transformers from insulation stress.

Multiple In Stock

Same day quotes

24/7 support

Protects Transformer Windings

Cuts down high-frequency voltage spikes from switching events before they can stress insulation and shorten transformer life.

Dampens Oscillation and Noise

The resistor turns transient energy into heat, quieting electrical ringing that can interfere with nearby equipment.

Backs Up Existing Protection

Snubbers catch the high-frequency stress that surge arresters and relays typically miss, adding a layer of protection rather than replacing what's already there.

Full Henka Support

Our team helps with product selection, TRV study interpretation, and same-day quotes.

Red R.C. Snubbers, Front View

Cutting-edge Engineering Products

Industry-leading solutions across Canada

These passive resistor-capacitor units dampen the voltage spikes that switching events send through medium-voltage transformers, keeping insulation protected in settings where breakers cycle often, motors start regularly, or loads shift throughout the day.
★★★★★

R.C. snubbers protect medium-voltage transformers from switching transients — ideal for breaker operations, motor starts, and frequent load changes.

High Quality Transformers

Power You Can Count On

Engineered for reliability and backed by a team that supports you 24/7, our transformers are built to keep your operations running without interruption – no matter the scale or sector.

Engineering
department

We design and develop innovative electrical solutions, ensuring safety, efficiency, and compliance with industry standards.

Aerial View Of Small Substation In Green Field, Top Down
High-voltage testing laboratories

Our laboratory verifies insulation integrity and performance under extreme conditions for reliable and certified results.

Substation With Energy Flow Light Visualization, Side V
Mobile Technical
Services

We provide on-site support, troubleshooting, and maintenance for electrical systems with upmost reliability and performance.

Workers Inspecting Industrial Facility Equipment, Side View
Top Quality
Repair Service
Maintenance & Installation
Emergency 24-7
Fast Support
Available for
Buy or Rent

Prevent Downtime and Protect Sensitive Equipment

Why Choose a RC-Snubber?

Henka UPS systems provide essential power backup that ensures business continuity during outages.

Wide Range

RC-Snubbers are common addition to medium-voltage transformers, industrial equipment with frequent switching, and motor control systems, working alongside surge arresters.

VFD Systems

RC-Snubbers are commonly paired with line and load reactors on variable frequency drive (VFD) systems, where they help limit switching transients and extend insulation life.

Also View Henka Transformers

Choose from On-line, Line-Interactive, and Standby Models

Solutions for Every Industry

From industrial facilities to commercial projects, our products are designed to handle the challenges of modern operations while ensuring safety and efficiency.

24/7 Full Support

Our professional team of experts are ready to handle your industrial power challenges and provide you with excellent customer services all year round.

Reliable Prooducts

Henka offers R.C. Snubbers as an authorized Rex Power Magnetics partner.

What is an R.C. snubber?
An R.C. snubber is a protective circuit built from a resistor and capacitor wired in series across transformer or reactor windings. It absorbs and softens the voltage spikes that switching events or circuit interruptions create, slowing the rate of voltage rise and easing the strain on insulation. This also cuts down on electrical noise elsewhere in the system. Used where switching is frequent or loads are pulsed, snubbers help transformers last longer and keep the system running reliably.
As close as possible. If there’s room, a snubber can be mounted directly inside a new transformer’s enclosure to keep the cable run as short as possible. On retrofits or standalone installs, keep the cable between the snubber and the transformer as short as you can. There’s no single maximum cable length that works for every system — a Transient Recovery Voltage (TRV) study is the only way to know how cable length will affect performance in your specific setup.
Every power system is different — load characteristics, equipment ratings, insulation levels, and voltage ranges all vary from one setup to the next. While general design guidelines exist, getting accurate resistor and capacitor values means running a Transient Recovery Voltage (TRV) study specific to your system. Those results are what let us size the components correctly and get the protection right. Contact Henka and we’ll help you work through the process.
R.C. snubbers show up in medium-voltage and industrial systems anywhere switching is frequent or transient currents run high — think capacitor banks, motor control centers, filter circuits, and power-factor correction equipment. They’re also commonly paired with line and load reactors on variable frequency drive (VFD) systems, where they help limit switching transients and extend insulation life.
When a transformer or reactor powers down, the energy stored in its windings can produce a sharp voltage spike at the terminals. The snubber’s resistor absorbs that energy and releases it as heat, while the capacitor keeps the voltage from rising too fast. Together, they stop the kind of voltage overshoot that damages insulation, triggers partial discharge, or wears out components early — and they help quiet electromagnetic interference in nearby equipment too.
Yes. Custom snubber assemblies can be built to match specific equipment ratings and transient energy levels, with options for resistance and capacitance values, voltage ratings, mounting dimensions, and connection methods. Every custom unit is engineered from real system transient data and tested to the same standards as our standard models. Contact Henka with your system parameters and we’ll get the process started.
Heavy Duty Power Transformer With Orange Details, Side View
Proudly Canadian Circular Badge With Red Leaf, Front Facing

Fill out the form and a member of our team will get back to you as soon as possible. We provide same day response during business hours.

Thousands of rental transformers

Looking for Temporary Power Solutions?

Request a quote to get a short-term high quality, reliable power unit with Henka Power rental options.
Heavy Duty Power Transformer With Orange Cap, Front View

Reliable for Every Industry

Innovative Power Solutions With Your Trusted Partners

Why Choose Henka Power for Dry-Type Transformers and UPS Systems?
From product selection to installation and maintenance, our team is here to make sure you’re supported every step of the way. Choose Henka for power solutions you can rely on, now and into the future.
Henka Logo Black And Yellow, Front View

Request a Quote

To receive an accurate quote for your dry-type transformers and UPS systems, please provide us with detailed information about the product type, including kVA rating specifications, primary and secondary voltages, and any other preferences. Our team will carefully review your request and deliver a customized quote.

Simply fill out the form below, and we’ll get back to you with a personalized quote tailored to your specific needs.

Multiple In Stock

Same day quotes

24/7 support